SpectraPro spectrographs use diffraction gratings as the optical element which separates (disperses) polychromatic white light into individual wavelengths (colors). When polychromatic light encounters the grating it is dispersed so that each wavelength reflects from the grating at a slightly different angle. Dispersed light is then reimaged by the monochromator or spectrograph so that individual wavelengths (or a desired band of wavelengths) can be directed to a detection system or sample. |
|
Grating
Groove
Density |
Grating
Blaze
Wavelength |
Optimum
Wavelength
Range |
|
SP 150
32x32mm |
|
SP 300i
68x68mm** |
|
SP-500i
68x68mm |
|
SP-750
68x68mm** |
50g/mm |
600nm |
400-1200nm |
150-05-600 |
1-05-600 |
1-05-600 |
750-1-05-600 |
75g/mm |
8µm |
5-l3µm |
|
1-075-8 |
1-075-8 |
750-1-075-8 |
l50g/mm |
300nm |
200-500nm |
150-015-300 |
1-015-300 |
1-015-300 |
750-1-015-300 |
l50g/mm |
500nm |
330-950nm |
150-015-500 |
1-015-500 |
1-015-500 |
750-1-015-500 |
150g/mm |
800nm |
475-1300nm |
150-015-800 |
1-015-800 |
1-015-800 |
750-1-015-800 |
150g/mm |
4µm |
2,6-6µm |
150-015-4 |
1-015-4 |
1-015-4 |
750-1-015-4 |
300g/mm |
300nm |
200-500nm |
150-030-300 |
1-030-300 |
1-030-300 |
750-1-030-300 |
300g/mm |
500nm |
330-900nm |
150-030-500 |
1-030-500 |
1-030-500 |
750-1-030-500 |
300g/mm |
1µm |
650-1800nm |
150-030-1 |
1-030-1 |
1-030-1 |
750-1-030-1 |
300g/mm |
2µm |
1,3-3µm |
150-030-2 |
1-030-2 |
1-030-2 |
750-1-030-2 |
600g/mm |
300nm |
200-500nm |
150-060-300 |
1-060-300 |
1-060-300 |
750-1-060-300 |
600g/mm |
500nm |
330-900nm |
150-060-500 |
1-060-500 |
1-060-500 |
750-1-060-500 |
600g/mm |
1µm |
650-1800nm |
150-060-1 |
1-060-1 |
1-060-1 |
750-1-060-1 |
600g/mm |
1,6µm |
1-2.4µm |
150-060-1,6 |
1-060-1-6 |
1-060-1-6 |
750-1-060-1,6 |
1200g/mm |
Holographic |
190-400nm |
150-120-HUV |
1-120-HUV |
1-120-HUV |
750-1-120-HUV |
1200g/mm |
300nm |
200-500nm |
150-120-300 |
1-120-300 |
1-120-300 |
750-1-120-300 |
1200g/mm |
500nm |
330-900nm |
150-120-500 |
1-120-500 |
1-120-500 |
750-1-120-500 |
1200g/mm |
750nm |
500-1400nm |
150-120-750 |
1-120-750 |
1-120-750 |
750-1-120-750 |
1200g/mm |
Holographic |
450-1400nm |
--- |
1-120-HVIS |
1-120-HVIS |
---
|
1800g/mm |
500nm |
330-850nm |
150-180-500 |
1-180-500 |
1-180-500 |
750-1-180-500 |
2400g/mm |
240nm |
190-450nm |
150-240-240 |
1-240-240 |
1-240-240 |
750-1-240-240 |
2400g/mm |
Holographic |
190-450nm |
150-240-HUV |
1-240-HUV |
1-240-HUV |
750-1-240-HUV |
2400g/mm |
Holographic |
450-700nm |
150-240-HVIS |
1-240-HVIS |
1-240-HVIS |
7 50-1-240-HVIS |
3600g/mm |
240nm |
190-450nm |
150-360-240 |
1-360-240 |
1-360-240 |
750-1-360-240 |
3600g/mm |
Holographic |
190-450nm |
150-360-HUV |
1-360-HUV |
1-360-HUV |
750-1-360-HUV |
Over 100 Additional Gratings are Available on Request for SpectraPro Monochromators and Spectrographs
** Standard grating size is 68x68mm with larger 68x84mm gratings available as an option 68x84mm gratings
preserve the light collecting power (aperture ratio) when operating at high wavelengths (high grating angles).
68x84mm gratings benefit operation above 1.2 µm with a 1200g/mm grating . |
|
|
|